Polyethylene lined iv tubing. 2 micron filter, male luer lock adapter and a single y-site.


Polyethylene lined iv tubing V. PVC IV tubing IV tubing comes in different lengths and sizes, connecting the IV bag to the patient. The new delivery system consisted of PEL tubing, a transparent PVC c … The aim of this study was to assess interactions between drugs and five alternative materials to a reference plasticized PVC intravenous (IV) infusion tubing: three were PVC coextruded with polyethylene (PE), polyurethane (PU) or a thermoplastic elastomer (Styrene-EthyleneButadiene-Styrene (SEBS)) and two were SEBS or thermoplastic olefin (TPO To prevent medication interactions and mitigate risks of exposure to DEHP (diethylhexyl phthalate)*, we offer: Polyvinyl chloride (PVC) and non-PVC tubing options, including: PVC (non-DEHP) - PU (polyurethane) - PE (polyethylene) - PE lined (PE/PVC) - Low sorbing (inner layer of PE and outer layer of PVC) - TPE (thermoplastic elastomers (consult specific SKU for specification). The polyethylene lined tubing allows content to flow freely without restriction caused by the tube material, eliminating the risk of backed up IV lines. The PVC pump segment and outer layer of polyethylene Set Length 200 cm Priming Volume 1. Baxter 2C7558 - SET IV CHEMOTHERAPY PACLITAXEL DEHP-FREE FLUID PATH PE LINED TUBING NON-VENTED 111IN SLIDE AND ROLLER CLAMP NEEDLE-FREE INJECTION PORT 0. Fluid path does Show More Dec 12, 2019 · The aim of this study was to assess interactions between drugs and five alternative materials to a reference plasticized PVC intravenous (IV) infusion tubing: three were PVC coextruded with Order IV Pump Set PlumSet™ Pump 2 Ports 15 Drops / mL Drip Rate 0. The tubing was 286 cm long, with a priming volume of 23 mL. 5 Yellow Striped Tubing, NRFit Single Channel Cassette 107 15 15 9. Our coextrusions of polyolefin-lined PVC tubes are world-renowned for medical gas and fluid transmission applications. Jun 8, 2023 · A slow rate of flow and long tubing length increase the loss of nitroglycerin. 1 Infusion bags/containers must be made of either polyvinylchloride (PVC), polypropylene (PP), polyethylene (PE) or polyolefin blend (PP+PE). Polyethylene I. 2 ml Bore 1 mm 1 Pinch Clamp (s) 1 Female Luer (s) 1 Male Luer (s) Low Sorbing Polyethylene lined PVC Natural rubber latex is not part of the material formulation DEHP is not part of the material formulation Quantity 40 A primary IV low-sorbing, polyethylene-lined tubing set (reference 2260-0500, Carefusion, Mississauga, Ontario [tubing set manufactured in Mexico]) was then connected to each bag. 6 m) Nitroglycerin Set DUO-VENT Spike with Polyethylene Lined Tubing and CLEARLINK Luer Activated Valve, Male Luer Lock Adapter. *Manufactured by Laboratorios Grifols S. It’s made from PVC, polyethylene, or polypropylene plastic. 3. 2 Micron Filter, Male Luer Lock Adapter, 10 drops/ml, 107" Length, Pump segment and fluid path does not contain DEHP; outer layer of polyethylene lined tubing c Jun 25, 2025 · Understanding Medication Sorption in IV Tubing The need for specialized IV tubing stems from sorption, a process where medication is lost from a solution. Nitroglycerin Set, DUO-VENT, CLEARLINK Luer Activated Valve, 60 drops/mL, 103" (2. Each one also has a 0. To circumvent the significant loss to PVC tubing, use of the special high-density polyethylene administration sets provided by the various nitroglycerin injection manufacturers is recom-mended. The Baxter single set can be used both as gravity and in the Sigma Spectrum Infusion pump throughout multiple care areas. This can happen through adsorption, where drug molecules stick to the tubing’s inner surface, or absorption, where the drug soaks into the plastic material itself. Nitroglycerin set Duo-Vent spike with polyethylene lined tubing and Clearlink® luer activated valve, male luer lock adapter Baxter IV Administration Sets are available in multiple configurations and drop rates. Buy discounted medical supplies at Vitality Medical. Our PE tubing contains no plasticizers or additives and meets FDA 21 CFR 177. Approximate Length 103" (2. PVC, or polyvinyl chloride, is commonly used to make IV tubing and bags (Viaflex, etc). administration set was compared with adsorption and delivery through an identical set composed of polyvinyl chloride (PVC) rather than PEL tubing. 2 micron filter, Clave™ Y-site, and secure lock male adapter. Low sorbing polyethylene tubing for infusion or aspiration Minimises the absorption of drugs into the tubing and prevents leaching Jun 22, 1984 · Nitroglycerin is absorbed in vitro into polyvinyl chloride tubing, and it has been recommended that nitroglycerin be administered intravenously through specialized polyethylene infusion sets. Fast shipping and low prices. 9 mm Pressure Sensor Disc 1 Female Luer (s) 1 Male Luer (s) Low Sorbing Polyethylene lined PVC Colour; Amber Natural rubber latex is not part of the material formulation Light Resistant Quantity 100 Order IV Pump Set Interlink® Pump 1 Port 10 Drops / mL Drip Rate 0. A. 2 Micron Filter, Male Luer Lock Adapter. A small bore polyethylene extension set that connects vascular access devices to luer lock devices. 7 m). 6 m). and distributed by ICU Medical Sales, Inc. Material To prevent medication interactions and mitigate risks of exposure to DEHP (diethylhexyl phthalate)*, we offer polyvinyl chloride (PVC) and non-PVC tubing options, including: PVC (non-DEHP) PU (polyurethane) PE (polyethylene) Low sorbing PE lined (PE/PVC) TPE (thermoplastic elastomers) Features Hanger Vented Paclitaxel Set with polyethylene lined tubing Site 6 from male Luer lock adapter Compatible with the COLLEAGUE Series Volumetric Infusion Pumps and FLO-GARD 6201 and 6301 Series Volumetric Infusion Pumps Fluid path does not contain DEHP; outer layer of polyethylene lined tubing contains DEHP. 1 Polyurethane (PU), polybutadiene (PBD), PVC, PP or PE You may see more focus on appropriate use of PVC-free and DEHP-free IV suppliesdue to shortages of some of these products. V sets and accessories designed for efficient and safe intravenous therapy. 22U FILTER 10GTTS/ML MALE LUER LOCK LATEX-FREE W/U490944R UR103 (48/CS) Search in: Submit Search Sign In/Register Polyethylene-Lined IV Extension Sets Manufacturer: BAXTER HEALTHCARE View Full Image Scroll to Top Jun 8, 2023 · A slow rate of flow and long tubing length increase the loss of nitroglycerin. Lectro-Spiral's coiled presentation offers the patient much more freedom of movement than a straight extension tube. 1 day ago · For sales inquiries, technical support and customer support complete the following form: Order IV Pump Set Outlook® Pump Without Ports 60 Drops / mL Drip Rate Without Filter 135 Inch Tubing by B. 8 cm) Extension Set with 0. 6. This research quantifies the problem in the context of clinical use. 2 Micron Down Stream High Pressure Extended Life Filter Polyethylene Lined Selected References These references are in PubMed. Braun V7450 To prevent medication interactions and mitigate risks of exposure to DEHP (diethylhexyl phthalate)*, we offer: Polyvinyl chloride (PVC) and non-PVC tubing options, including: PVC (non-DEHP) - PU (polyurethane) - PE (polyethylene) - PE lined (PE/PVC) - Low sorbing (inner layer of PE and outer layer of PVC) - TPE (thermoplastic elastomers (consult specific SKU for specification). 1520 and USP class 6 requirements. Particularly recommended for use when transporting patients receiving infusions, for children (for all types of I. Mar 28, 2022 · DEHP-free means a product, typically plastic, does not contain di (2-ethylhexyl)phthalate (DEHP), a plasticizer often used in polyvinyl chloride (PVC). Straight-Type Extension Set, 0. chcYou need to enable JavaScript to run this app. Secondary IV Administration Set ICU Gravity 40 Inch Tubing SECONDARY SET, PE LINED LIGHT RESIST TUBE SECURE LOCK (50/CS Order IV Pump Set Clearlink™ Pump 1 Port 10 Drops / mL Drip Rate 0. Adsorption and delivery of nitroglycerin through a new polyethylene-lined (PEL) i. 2 micron filter, Clave™ Y-site and secure lock male adapter. Discussion Principal Findings A good example of the absolute need for the correct selection of administration line for a particular medication is that of epoprostenol. 2 Micron Filter, Polyethylene Lined Tubing . Material To prevent medication interactions and mitigate risks of exposure to DEHP (diethylhexyl phthalate)*, we offer polyvinyl chloride (PVC) and non-PVC tubing options, including: PVC (non-DEHP) PU (polyurethane) PE (polyethylene) Low sorbing PE lined (PE/PVC) TPE (thermoplastic elastomers) Baxter 2C8858 - Paclitaxel Set, Non-Vented Spike, Polyethylene Lined Tubing, Clearlink Luer Activated Valve, 0. 2-micron filtration and reacts with polyethylene (which is commonly used in low-sorbing lines). We would like to show you a description here but the site won’t allow us. extension tubes. The Clave Y-Site of the line is the connecting point for the secondary line. Jul 28, 2025 · SUMMARY DARZALEX should be administered by a healthcare professional, with immediate access to emergency equipment and appropriate medical support to manage infusion reactions if they occur. Explore a range of BD I. 2" (15. 2 Micron Filter 107 Inch Tubing by Baxter 2R8858 For sales inquiries, technical support and customer support complete the following form: Paclitaxel Set Vented Spike with Polyethylene Lined Tubing and INTERLINK Injection Site, 0. Learn what tubing to use for nitroglycerin to ensure patient safety. Every set-up and change of IV tubing carries a risk of touch contamination. 5 ml Bore 0. catheterisation) and adults under I. Approximately 10 drops/mL. These precipitates have been observed in the infusion tubing distal to the pump chamber. METHOD: Experimental insulin adsorption data from literature is used to calculate insulin delivery and total insulin adsorption capacities for polyethylene (PE) and polyvinal chloride (PVC) lines at clinically relevant flow rates and concentrations. To determine if tubing type is essential to achieve physiologic effectiveness, we studied dose responses to … Get the right IV solution container, in the right size, and free of PVC, DEHP, and latex. Set Length 150 cm Priming Volume 1. 22 Micron Filter 108 Inch Tubing by Baxter 2C7558 Non-Vented Paclitaxel Sets from Baxter feature polyethylene lined tubing with an INTERLINK injection site. Excelon Bev-A-Line IV ® Tubing Bev-A-Line IV ® tubing is a lightweight, high clarity, transparent tubing, which provides higher-pressure and vacuum capabilities than other products on the market. Polyethylene polymers are lightweight, chemically inert, and impermeable, making them ideal for catheter tubing as well as for packaging materials, such as coil hoops. PVC, or p oly v inyl c hloride, is commonly used to make IV tubing and bags (Viaflex, etc). Primary IV Administration Set Baxter Gravity 3 Ports 10 Drops / mL Drip Rate Without Filter 119 Inch Tubing Solution Without Flow Regulator SOLUTION SET, DUO VENT SPIKE 3VALVES 119" (48/CS) Order IV Administration Sets and other in-stock IV Administration supplies and products for your care setting through the McKesson SupplyManager portal. These include polyolefins, such as polypropylene and polyethylene, thermoplastic polyurethanes (TPUs), thermoplastic elastomers (TPEs), and ethylene-vinyl acetate (EVA). Primary Nonvented IV SetManufacturer: BAXTER HEALTHCARE View Full Image Nov 20, 2025 · Nitroglycerin is absorbed by standard PVC tubing, making correct tubing selection critical for accurate dosing. Polyethylene Medical Tubing High density (HDPE), low density (LDPE), and linear low density polyethylene (LLDPE) are among the common PE polymers used for medical applications. While using less absorptive tubing (i. The tubing is coextruded to combine the benefits of two tubes in one seamless product. Primary PlumSet™ — with polyethylene-lined tubing, convertible piercing pin and sight chamber, 2 slide clamps, cassette with capped secondary port, 0. 2 Micron Filter* Order IV Pump Set PlumSet™ Pump 2 Ports 103 Inch Tubing by ICU Medical 15339-28 Vented Paclitaxel Set with Polyethylene Lined Tubing, INTERLINK Injection Site is in stock now at ready to ship. e. 0. 1220 PACLITAxEL concentrations. 2R8858 Paclitaxel Set, Non-Vented with Polyethylene Lined Tubing, 0. Primary PlumSet with polyethylene-lined tubing, convertible piercing pin and sight chamber, 2 slide clamps, cassette with capped secondary port, 0. 2 micron filter, male luer lock adapter and a single y-site. v. 5 Yellow Striped Tubing, Medical Grade Polyethylene micro-tubing has excellent chemical and gas resistance. This phenomena is dif-ferent from, but similar to, aggregation, which is the binding of insulin to itself. To determine if tubing type is essential to achieve physiologic effectiveness, we studied dose responses to intravenous nitroglycerin in 15 patients with heart failure using standard polyvinyl chloride We would like to show you a description here but the site won’t allow us. therapy at home. 3 Yellow Striped Tubing Single Channel Cassette 107 15 13 6. Order IV Pump Set PlumSet™ Pump 3 Ports 15 Drops / mL Drip Rate Without Filter 107 Inch Tubing by ICU Medical 14248-28 Set Length 285 cm Priming Volume 25 ml Bore 3 mm 1 Spiked Drip Chamber (s) (Vented/Unvented) Drops per ml 20 Hydrophobic Air Inlet Filter (with Cap) Vented Filter 1 Pinch Clamp (s) AccuSlide™ Flow Regulator Tested for use with Paclitaxel (Taxol™) 0. Sterile Fluid Path. The infusion sets were primed with insulin solution, so that all air bubbles were eliminated. You’ll need to know when to use PVC-free and DEHP-free IV supplies during sterile compounding. Learn more about BD INTRAMEDIC™ Polyethylene Tubing (Sterile) PE# 240 and other BD products today. . Approximately 60 drops/mL. Approximate length 107" (2. This may not be the complete list of references from this article. 1716 Although precip-itation of insoluble drugs in an aqueous medium is a foregone conclusion, the time to precipitation is irregular. 2 Micron Filter 104 Inch Tubing Solution by ICU Medical 1425628 Explore BD I. Administration Sets Administration sets help to reliably administer IV fluids and drugs to patients. 2 µm Inline Filter 1 Male Luer (s) Rotating Male Luer (s) Low Sorbing Polyethylene lined PVC Natural rubber latex is not part of the material Secondary infusion sets including many types of tubing and various configurations that integrate needle-free connectors including SmartSite™ and Texium™ connectors. Discover how to choose the right plastic medical tubing for various applications based on safety, performance, and biocompatibility. Nitroglycerin is absorbed in vitro into polyvinyl chloride tubing, and it has been recommended that nitroglycerin be administered intravenously through specialized polyethylene infusion sets. polyethylene or polypropylene) when administering nitroglycerin is recommended, most published clinical studies looking at nitroglycerin have used PVC tubing. V Sets and Accessories for reliable infusion solutions, featuring advanced designs and materials for various medical applications. Non-DEHP Pump Segment. The Single Set Technology can reduce the number of set-ups and teardowns which can decrease the Insulin adsorption, or binding, to delivery sur-faces, such as glassware,17,18 syringes,4,19 IV bags,5,13,18,20 deliv-ery tubing, and catheters,3,6,8-10,16,18,21 removes insulin that would otherwise be delivered to the patients. This medication requires light protection and 0. 2 Micron Downstream Filter, Polyethylene Lined Tubing, Male Luer Lock Adapter.